Name | Type | Posted | Actions |
|---|---|---|---|
https://dodprocurementtoolbox.com/ | LINK | Aug 15, 2025 | |
https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf | LINK | Aug 15, 2025 | |
https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml | LINK | Aug 15, 2025 | |
https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=W911S225U1611¬iceType=CombinedSynopsisSolicitation | LINK | Aug 15, 2025 |
SANDING BOOTH SYSTEM
Contact and place of performance
David Fortune
74501
Implemented Amendment to include Set Aside Code from N/A to Total Small Business Set-Aside. Purchase Description for a Sanding BoothScopeThe following document provides the requirements and specifications for the sanding booth.Applicable Documents1. Standards and Regulations:a. NFPA 33b. OSHA CFR-29.1910.1072. Additional DocumentsRequirements3. General RequirementsThis section provides the design specification requir...
View moreThe Department of the Army, MICC-Fort Drum, is soliciting for a sanding booth system under solicitation number W911S225U1611. This procurement is a combined synopsis/solicitation designated as a Total Small Business Set-Aside (SBA) and is classified under NAICS code 333413, Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing, and PSC 3426, METAL FINISHING EQUIPMENT. Responses are due by August 22, 2025, and David Fortune serves as the point of contact.
The required sanding booth must feature two-stage filtration and accommodate a monorail system through a five-inch overhead gap between front and back sections. The interior working area must measure 7 feet wide by 9 feet 6 inches high by 36 inches deep, with overall outside dimensions of approximately 7 feet 4 inches wide by 10 feet 2 inches high by 12 feet 2 inches deep. Construction specifications include 18-gauge reinforced steel panels with galvanized flanges, high-efficiency LED lighting, and an exhaust system featuring a 36-inch diameter tube-axial fan rated at 15,525 CFM.
Filtration for the unit must include a blanket-style poly roll media first stage and a pocket filter second stage, with an on-board manometer to display air resistance. The exhaust assembly includes a fan connector ring, an inspection plate, a 90-degree elbow for horizontal flow, and an exterior wall-mount louvered damper. All equipment must adhere to NFPA 33 and OSHA CFR-29.1910.107 standards for safety and performance.