LTUY252022 Repair B37 MTS by Removal
Contact and place of performance
MSgt Joe Bernier
Saint Louis, MO 63125
USA
This project is to repair Building 37 on Jefferson Barracks ANGS so that its primary and backup electrical systems function correctly in the event of a power outage. The building has an outdoor transfer switch that does not connect to a generator. During an outage, the transfer switch disconnects the building from the transformer but does not switch back to commercial power once restored. This project removes wiring...
View moreUpdate 20 May 2026: Amendment 2 and a partial floor plan drawing added to files. The floor plan is provided for informational purposes only and the Government doesn't guarantee the accuracy of the dimensions provided.
The Department of the Army, specifically the W7NJ USPFO Activity MOANG 131, is soliciting for a project to repair Building 37 at Jefferson Barracks Air National Guard Station in Saint Louis, Missouri. The primary objective is to restore the building's electrical systems to ensure they function correctly during and after power outages. Currently, an outdoor transfer switch fails to reconnect to commercial power once restored; this project requires the removal of wiring from that switch and the restoration of the power feed from the transformer to its original configuration prior to the switch installation.
This solicitation, identified by number W50S8K26QA001, is designated as an SBA (Small Business Administration) set-aside. The project is classified under NAICS 238210, Electrical Contractors and Other Wiring Installation Contractors, and PSC Z2AZ, Repair or Alteration of Other Administrative Facilities and Service Buildings. MSgt Joe Bernier serves as the point of contact for this requirement.
The response deadline for this solicitation is May 27, 2026. Ten attachments are associated with the notice, including RFI responses, tax exemption documentation, electrical diagrams, and two amendments. These files include a basement drawing and a partial floor plan provided for informational purposes. National Guard data regarding the time required to definitize equitable adjustments for construction change orders is currently unavailable but will be provided in future announcements.