Name | Type | Posted | Actions |
|---|---|---|---|
Solicitation Amendment FA301620R00770003 SF 30.pdf | Aug 20, 2020 | ||
Solicitation Amendment FA301620R00770002 SF 30.pdf | Aug 17, 2020 | ||
Hangar Fire Suppression Questions.pdf | Aug 17, 2020 | ||
Solicitation Amendment FA301620R00770001 SF 30.pdf | Aug 10, 2020 | ||
Performance Work Statement (PWS) - JBSA AHFSM 10 Aug.pdf | Aug 10, 2020 | ||
Bexar Country WD 2015-5253 - Rev 11 - 27 June.pdf | Jul 30, 2020 | ||
Solicitation - FA301620R0077.pdf | Jul 30, 2020 | ||
Performance Work Statement (PWS) - JBSA Aircraft Hangar Fire Suppression Systems Maintanence.pdf | Jul 30, 2020 |
JBSA Hangar Fire Suppression Maintenance
JBSA Hangar Fire Suppression Maintenance
Contact and place of performance
Keegan Hoover
JBSA Lackland, TX 78236
USA
Amendment 0003 1. Proposals are now due by 25 August 2020, 4 PM Central Amendment 0002 1. Proposals are now due by 21 August 2020, 4 PM Central 2. Provide Answers to provided questions Amendment 0001 1. Proposals are now due by 19 August 2020, 4:00 PM Central 2. The requirement for services at JBSA Lackland Building 820 and Hangar 829 have been removed in their entirety. (Attached is the updated PWS dated 10 August 2...
View moreThe Department of the Air Force, specifically the 502 CONS CL, is soliciting proposals for aircraft hangar fire suppression maintenance at Joint Base San Antonio (JBSA), Texas. This requirement, identified under solicitation number FA301620R0077, is designated as a Service-Disabled Veteran-Owned Small Business (SDVOSBC) set-aside. The work falls under NAICS code 238220 for Plumbing, Heating, and Air-Conditioning Contractors and PSC Z1BZ for maintenance of other airfield structures. Proposals are due by August 25, 2020, at 4:00 PM Central Time, and the primary point of contact for this solicitation is Keegan Hoover.
The scope of work involves inspections, testing, and maintenance of fire suppression systems, alarms, and components across multiple facilities at JBSA Randolph and JBSA Lackland. Specific tasks include servicing drainage discharge gates, fire pumps, diesel engines, storage tanks, and various fire protection systems such as Aqueous Film Forming Foam (AFFF) and High Expansion Foam (HEF). Performance must comply with Unified Facilities Criteria (UFC) 3-601-02, NFPA 25, and NFPA 409 standards. Following amendments to the requirement, services at JBSA Lackland Building 820 and Hangar 829 were removed from the project scope.
Contractors must be licensed to perform inspection and maintenance on wet-pipe fire protection, fire alarm control panels, and backflow devices, and they must be certified to test and report diesel engine emissions. The solicitation includes eight attachments, such as the updated Performance Work Statement (PWS) dated August 10, 2020, Bexar County wage determinations, and multiple solicitation amendments. All work is to be performed at JBSA Lackland and JBSA Randolph in San Antonio, Texas.