SOURCES SOUGHT NOTICE Notice Type: Sources Sought / Request for Information (RFI) Title: Switchboard and Motor Control Center (MCC) Panel Replacement Service Location: ALTESS Data Center, Radford Army Ammunition Plant, Radford, VA 1.0 Introduction and Purpose This is a Sources Sought Notice issued for market research and planning purposes only. This is NOT a solicitation, Request for Proposal...
View moreSpecific Tasks:
Room 119 Equipment Removal & Installation Services:
Westinghouse Fused Switchboard and Motor Control Center (MCC): Westinghouse fused switchboard and motor control center (MCC) panel replacement service shall include:
Room 241 Equipment Removal & Installation Services:
3.0 Requested Capability Statement
Interested parties are requested to submit a Capability Statement demonstrating their ability to perform the services described in the SOW. Please provide the following information structured in your response:
Requirement Category
Specific Information Requested
Company Profile
Company Name, Address, CAGE Code, and Unique Entity ID (UEI).
Point of Contact
Name, Title, Phone Number, and Email Address of the primary representative.
Business Size & Socio-Economic Status
Specify your business size under the applicable NAICS code (238210 - Electrical Contractors) and any applicable socio-economic categories (e.g., 8(a), SDVOSB, WOSB, HUBZone).
Technical Capability
Detailed narrative demonstrating the capability to provide, install, and customize Eaton (or equal) switchboards/MCCs. Must explicitly address the ability to provide a certified Trane Authorized Controls technician and integrate with Schneider Electric StruxureWare.
Logistics & Security
Statement of ability to conduct required after-hours/weekend repowering work and comply with Radford Army Ammunition Plant (RFAAP) security and background check requirements.
Past Performance
Briefly describe up to three (3) similar projects completed within the last five (5) years involving data center power infrastructure replacement, BAS integration, and secure facility operations.
4.0 Submission Instructions
Responses should be concise and focused on the capability to meet the Government's requirements.
Submission Detail
Instruction
Page Limit
Maximum of ten (10) pages.
Document Format
PDF or Microsoft Word format.
Submission Email
KO [email protected], CS [email protected], and CC: [email protected] (COR)
Response Deadline
Thursday, May 21, 2026 at 12:00 PM EST
Subject Line
Sources Sought Response: ALTESS Switchboard & MCC Replacement
Disclaimer: Information received in response to this notice will be used solely for market research and acquisition strategy planning. Proprietary information, if any, should be minimized and MUST BE CLEARLY MARKED. To aid the Government, please segregate proprietary information
The Department of the Army, specifically the MICC Fort Lee office, has issued a sources sought notice to identify qualified contractors for switchboard and Motor Control Center (MCC) panel replacement services. This market research initiative supports the ALTESS Data Center located at the Radford Army Ammunition Plant in Radford, Virginia. The required services fall under NAICS 238210, Electrical Contractors and Other Wiring Installation Contractors, and PSC J030, Maintenance, Repair, and Rebuilding of Equipment: Mechanical Power Transmission Equipment. There is currently no set-aside designated for this potential procurement.
The scope of work involves the removal of legacy Westinghouse and GE switchboards and MCC panels from Rooms 119 and 241 and the installation of new, customized Eaton or equivalent equipment. The contractor must provide temporary power for critical systems, such as hot water pumps and sewer ejection compressors, during the transition. Integration requirements include maintaining and reinstalling controls wiring for Trane Building Automation Systems and Schneider Electric StruxureWare monitoring. All BAS-related work must be verified and recommissioned by a certified Trane Authorized Controls technician. Additional tasks include performing an arc flash, short circuit, and coordination study for the entire facility and managing the offsite disposal of all legacy hardware and debris.
The anticipated period of performance for this project is July 1, 2026, through June 30, 2027. Work involving the repowering of existing panels must be scheduled after hours or on weekends when the facility is unoccupied. Interested parties must submit capability statements by May 21, 2026. Submissions should demonstrate the firm's technical ability to perform the installations and their capacity to comply with the security and background check requirements of the Radford Army Ammunition Plant. The primary point of contact for this notice, identified under solicitation number W91QF526QA004, is Ryan Lancaster.