Defense Supply Center Richmond (DSCR) B66 BBQ Pit Repairs
Contact and place of performance
Benjamin Maxwell
Richmond, VA 23227
USA
Combined Synopsis/Solicitation for commercial goods and services IAW FAR part 12. Defense Supply Center Richmond (DSCR) Building 66D BBQ Pit Repairs This is a solicitation for construction prepared in accordance with the format in FAR Part 36, as supplemented with additional information included in this notice. The solicitation number SP4703-26-Q-0028 is issued as a request for quote (RFQ). ...
View more3. SPECIFIC REQUIREMENTS
The contractor shall:
Demolition
• Dismantle and dispose of the existing brick BBQ grill, demolished materials may be reused for the new BBQ grill construction with approval of the FRIE Project Manager.
• Sawcut, demolish, and remove the existing concrete foundation from the existing construction joint. The existing slab is approximately 7.5’-0” x 10’-0” x 0’10” thick (contractor to verify in field). The contractor is not to demolish or damage any concrete related to the existing pavilion foundation.
• Ensure proper disposal of all debris in accordance with local regulations.
Site Preparation
• Install temporary barriers or signage to secure the work area.
• Clear and level the site after demolition.
• Compact native soil.
• Compact a minimum 6” sub-base consisting of crusher run or dense grade aggregate (DGA) in 3” lifts.
• Compact a minimum on 6” #57 stone in 3” lifts.
Foundation Construction
• Pour new 8.5’-0” x 12’-0” x 1’-6” thick concrete Slab on Grade foundation in accordance with UFC 3-301-01 consisting of 4000 psi concrete and a minimum of #6 grade 60 steel reinforcing at 12” on center, each way. Use standard broom finish per the above UFC.
• Ensure new top of slab on grade is level with existing pavilion foundation.
• Install new expansion joint between new slab on grade and existing slab on grade, where the demolition saw cut was made.
• Ensure proper curing and finishing to prevent future cracking or settling.
BBQ Grill Construction
• Construct new brick BBQ grill in accordance with UFC 3-110-03.
• Ensure minimum 1’-0” clear space between new BBQ grill and edge of new concrete slab on grade.
• Incorporate design features such as firebox, chimney, and grill grates to match existing BBQ grill.
This acquisition is set-aside for 100% small businesses. The North American Industry Classification System (NAICS) Code is 238140 (Masonry Contractors). The small business size standard is $19M.
Department of Labor Wage Determination based on location of the service provided (Richmond, VA). Partial proposals will not be accepted.
For an offer to be considered for award, the contractor must own, possess, or otherwise control a bona fide place of
business from which mobilization occurs within 125 miles of Defense Supply Center Richmond. A bona fide place of
business refers to a location where the offeror regularly maintains an office with at least one full-time employee.
The offeror must include the address of this location in its bid.
Award will be made to the lowest priced, technically acceptable (LPTA) offeror that meets the requirements stated in the Statement of Work and the solicitation. Also refer to clauses and provisions included in this notice. Past performance will be considered a part of Technical Acceptability, and the Contracting Officer will pull contractor data from CPARS and SPRS.
The contractor must be registered in the System for Award Management (SAM) prior to award. If not already registered in SAM, go to the SAM website www.sam.gov to register prior to submitting your quote.
Acceptable method of quote or inquiries submission is Email to [email protected].
A site visit will be held 04/08/2026 @1000. See p.46 of SOW for DSCR map for location of DSCR B46 meeting location and parking location. There is a map at the end of the SOW. On the right side you should see a building marked "66" in front is a greyed out rectangular shape, this will be the best parking location for you. Once it hits 1000 we will walk around to the BBQ Pit together.
In order to attend the site visit interested parties MUST follow the instructions below no less than 5 business days
prior to the site visit. This is to allow time for vetting by base security. Plan on arriving at DSCR an hour prior
to the site visit time, as the processing time through the visitor center fluctuates. Follow the link below to
register through DBIDS, and a QR code should be provided for each visitor. The QR codes MUST be emailed to the
Project Manager, Robert Miller <[email protected].> (Work Cell: (804) 239-6891). The QR code MUST be emailed to the project manager as soon as possible due to the lengthy vetting process of approximately 5 business days. The project manager will also serve as the sponsor for site visit attendees.
A new system was implemented on 3 January 2023 to screen visitors and contractors for installation access at DSCR. The new system is designed to increase efficiencies, enhance the protection of personal information during the vetting process and eliminate the use of hard copy DLA Form 1815s. The new screening system will require visitors and contractors to pre-enroll in DBIDS (Defense Biometric Identification System). To begin the process, visitors and contractors will complete registration through the pre-enrollment website:
https://dbids-global-enroll.dmdc.mil.
Upon entry of their information, visiting personnel will be provided an electronic form to download, which will have
an individualized barcode and alpha numeric code. The codes need to be sent to the visiting person’s
sponsor. Once in receipt of the barcode, the sponsor will email Security and Emergency Services and provide the
barcode and sponsorship information. Once the visitor/contractor is vetted and approved for installation access,
Security & Emergency Services will notify the sponsor that the visitor/contractor can go to the DSCR Visitor Center to
obtain his/her pass. At the Visitor Center, the visitor provides the barcode and code provided earlier in the process
and completes the credentialing process.
See attached SOW for full requirement details. Parties interested in submitting a quote for this project are advised
and expected to have reviewed the entire SOW prior to site visit attendance.
Questions are due on 13APR26, end of day. Submit questions via email to [email protected].
Quotes are due 20APR26, end of day.
The point of contact (POC) for this requirement is Benjamin Maxwell ([email protected]).
Reference Attachment 1 - Statement of Work (SOW) for additional work scope and details.
Period of Performance:
90 days from Notice to Proceed
MAGINITUDE OF CONSTRUCTION
36.204 Disclosure of the magnitude of construction projects. | Acquisition.GOV
In accordance with FAR Part 36.204(b), the estimated Magnitude of Construction for this contract is between $25,000 and $100,000.
The Defense Logistics Agency, DCSO Richmond Division #1, has issued a combined synopsis/solicitation under solicitation number SP470326Q0028 for the repair of the Building 66 barbeque pit at the Defense Supply Center Richmond (DSCR) in Virginia. This project involves restoring the structural integrity and functionality of an existing outdoor grill area through the demolition and removal of a deteriorating concrete foundation and brick BBQ grill. The contractor will be responsible for site preparation, including soil compaction and sub-base installation, followed by the construction of a new 8.5’ x 12’ x 1.5’ reinforced concrete slab and a new brick BBQ grill featuring a firebox, chimney, and grates to match the existing design.
This acquisition is set-aside 100% for Small Business Administration (SBA) participants under NAICS code 238140, Masonry Contractors, with a corresponding PSC of Z2PZ for Repair or Alteration of Other Non-Building Facilities. The government intends to award a firm-fixed price contract to the lowest priced, technically acceptable (LPTA) offeror. To be eligible for award, contractors must maintain a bona fide place of business with at least one full-time employee within 125 miles of DSCR. The estimated magnitude of construction is between $25,000 and $100,000, and the performance period is 90 days following the Notice to Proceed.
The response deadline for this request for quote is April 21, 2026, with questions due by the end of the day on April 13, 2026. A site visit is scheduled for April 8, 2026, and requires pre-registration through the Defense Biometric Identification System (DBIDS) at least five business days in advance. Submissions and inquiries should be directed to the point of contact, Benjamin Maxwell. The solicitation includes three attachments: a Statement of Work (SOW), a Department of Labor wage determination for Richmond, VA, and the SF1449 solicitation form.
Generated by Lumen AI
Scoped analysis and attachments—go beyond the summary when you need detail from the solicitation package.