Name | Type | Posted | Actions |
|---|---|---|---|
Attachment 5 Questions from Industry REV 1.pdf | May 7, 2026 | ||
1232SA26Q0470 Amend 3.pdf | May 7, 2026 | ||
1232SA26Q0470 Amend 2.pdf | May 7, 2026 | ||
Attachment 5 Questions from Industry.pdf | May 7, 2026 | ||
1232SA26Q0470 Amend 1.pdf | Apr 22, 2026 | ||
Attachment 4 Drawings.pdf | Apr 20, 2026 | ||
SF 1442 1232SA26Q0470.pdf | Apr 20, 2026 | ||
Attachment 1 Statement of Work.docx | DOCX | Apr 20, 2026 | |
Attachment 3 WD IA20250003 Mod 0 Dated 2 Jan 2026.pdf | Apr 20, 2026 | ||
Attachment 2 Specifications.docx | DOCX | Apr 20, 2026 | |
SF 1442 1232SA26Q0470.pdf | Apr 20, 2026 |
Pumped Pretreated Waste System Vault Upgrade Project – Ames, IA
Contact and place of performance
David Hildebrand
Ames, IA 50010
USA
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotations are being requested and a separate written solicitation will not be issued. Solicitation number 1232SA26Q0470 is issued as a Request for Quotation (RFQ) for The work includes replacing all the carbon steel piping componen...
View moreQuestions shall be submitted via emailed to [email protected] and are due no later than April 30, 2026 at 12:00 PM Central time. This will ensure enough time to respond before the solicitation period ends. Please include the solicitation name and number as the subject line of the email.
The United States Department of Agriculture, Agricultural Research Service, has issued solicitation number 1232SA26Q0470 as a Request for Quotation for the Pumped Pretreated Waste System Vault Upgrade Project in Ames, Iowa. This requirement involves the replacement of all carbon steel piping components within Vaults 101B, 103, and 105 at the USDA Campus with stainless steel components. The project scope further includes replacing all existing valves with new stainless steel full-port ball valves and insulating all piping within the vaults. Performance occurs at 1920 Dayton Avenue, and while Vault 105 is available for scheduled site visits, the remaining two vaults are restricted until after award due to decontamination requirements.
This acquisition is a total small business set-aside under code SBA. The project is classified under NAICS 237110 Water and Sewer Line and Related Structures Construction and PSC Z2ND Repair or Alteration of Sewage and Waste Facilities. Supporting documentation for this solicitation includes 11 attachments, such as technical drawings, industry questions, and multiple amendments issued between April 20 and May 7, 2026.
Quotations must be submitted by the response deadline of May 12, 2026. The point of contact for this solicitation is David Hildebrand, and the agency previously established a deadline of April 30, 2026, for the submission of technical questions. This combined synopsis/solicitation is conducted for commercial items following FAR Part 12 procedures, and all responsible sources may submit a quotation for consideration.
Generated by Lumen AI
Scoped analysis and attachments—go beyond the summary when you need detail from the solicitation package.